Minco point sensitive RTDs are RoHS compliant and feature surface or pressure-sensitive mounting, and polyimide, silicone rubber or Mylar™ insulation. They also feature waterproof constructions suitable for continuous immersion and standard PTFE or silicone rubber insulated lead wire options as well as stainless steel braid over lead wires.
For applications requiring:
Element Type | Platinum |
Resistance | 1,000 Ω ±0.12% at 0°C |
TCR | 0.00385 Ω/Ω/°C |
Dimensions | 0.20 x 0.60 x 0.08" (5 x 15 x 2 mm) |
Thickness (in) | 0.080 |
Length (in) | 0.600 |
Width (in) | 0.200 |
Lead Length (in) | 36 |
# Leads | 2 |
Backing | No Adhesive |
Lead Wire | AWG# 26 |
Base Model | S100820 |
Element Code | PF |
Temperature Range | -50 to 260°C (-58 to 500°F) |
Body Material | Polyimide film |
Lead Insulation | PTFE |
Type | Thermal-Tab |
Lead Bulge | Tmax is measured over the lead bulge |
Documentation | |
Technical Specification | MCTS Thermal-Tab and Thermal-Ribbon S... |